High voltage switchgear refers to the equipment used for power generation, transmission, distribution, energy conversion, and consumption in the power system to perform functions such as on/off, control, or maintenance. High voltage switchgear is divided into fixed and movable types according to the installation method of the main components inside the cabinet, abbreviated as fixed cabinet and handcart cabinet. The movable high-voltage switchgear can be divided into two types based on the orientation of the handcart: floor mounted and center mounted. Classified by safety level, it is divided into armored, interval, and box type. According to the main insulation medium inside the cabinet, it is divided into air insulated cabinet and gas insulated cabinet (inflatable cabinet).
Let's take a look at the issues that need to be paid attention to in high-voltage switchgear:
1. After the vacuum circuit breaker car inside the high-voltage switchgear is closed in the experimental position, the car circuit breaker cannot enter the operating position. (Avoid closing under load)
2. When the grounding knife in the high-voltage switchgear is in the closed position, the car circuit breaker cannot be closed. (Avoid closing with grounding wire)
3. The vacuum circuit breaker inside the high-voltage switchgear cannot exit the operating position of the trolley circuit breaker during operation. (Avoid loading the knife switch)
4. During the closing operation of the vacuum circuit breaker inside the high-voltage switchgear, the back door of the cabinet is locked with a mechanical device on the grounding knife to the cabinet door. (To avoid accidentally entering the charged interval)
5. The vacuum circuit breaker inside the high-voltage switchgear is closed during operation, and the grounding knife cannot be put into operation. (Avoid connecting live grounding wires)
Article source: Jiangmen distribution box muaizuowen.com
02-28
What are the safety technical requirements for Jiangmen substation cabinets
Assembling switchgear, measuring instruments, protective appliances, and auxiliary equipment into enclosed or semi enclosed boxes or screens forms a distribution box. What are the safety technical req
02-28
Installation environment requirements for Jiangmen substation cabinets
In the process of our practical installation, if the orientation of the distribution box is not very perfect or does not meet the requirements of the practical site, the installation personnel should
02-28
Wiring principles of Jiangmen distribution box
We cannot do without electricity. We use electricity almost every day, and electricity has become an indispensable part of our daily lives. Today, we will introduce the wiring guidelines for distribut
02-28
How to deal with the tripping of Jiangmen distribution box
Reason for tripping of distribution box:1. Check if the air switch is damaged.2. Check if the air switch wiring is correct. Incorrect and rewire.3. Check the insulation of the circuit on the load side